P0134 ACURA O2 Sensor Circuit No Activity Detected Bank 1 Sensor 1

Possible causes – Faulty Front Heated Oxygen Sensor Bank 1– Front Heated Oxygen Sensor Bank 1 harness is open or shorted– Front Heated Oxygen Sensor Bank 1 circuit poor electrical connection– Inappropriate fuel pressure– Faulty fuel injectors– Intake air leaks may be faulty– Exhaust gas leaks Tech description Replacing the Front Heated Oxygen Sensor Bank…

P0154 ACURA A/F Sensor 21 Heater System Malfunction

Possible causes – Faulty Front Heated Oxygen Sensor Bank 2– Front Heated Oxygen Sensor Bank 2 harness is open or shorted– Front Heated Oxygen Sensor Bank 2 circuit poor electrical connection– Inappropriate fuel pressure– Faulty fuel injectors– Intake air leaks may be faulty– Exhaust gas leaks Tech description Replacing the Front Heated Oxygen Sensor Bank…

P0389 ACURA Crankshaft Position Sensor B Intermittent Interruption

Possible causes – Faulty crankshaft position sensor– Crankshaft position sensor harness is open or shorted– Crankshaft position sensor circuit poor electrical connection– Signal plate may be damage– Starter motor may be faulty– Starting system circuit– Dead or weak battery Tech description Sometimes and in some models, low battery voltage or a weak starter can can…

P0385 ACURA Crankshaft Position Sensor B No Signal

Possible causes – Faulty crankshaft position sensor– Crankshaft position sensor harness is open or shorted– Crankshaft position sensor circuit poor electrical connection– Signal plate may be damage– Starter motor may be faulty– Starting system circuit– Dead or weak battery Tech description Sometimes and in some models, low battery voltage or a weak starter can can…

P0339 ACURA Crankshaft Position Sensor A Circuit Intermittent

Possible causes – Faulty crankshaft position sensor– Crankshaft position sensor harness is open or shorted– Crankshaft position sensor circuit poor electrical connection– Signal plate may be damage– Starter motor may be faulty– Starting system circuit– Dead or weak battery Tech description Sometimes and in some models, low battery voltage or a weak starter can can…

P2101 ACURA Throttle Actuator System Malfunction

Possible causes – Faulty Electric Throttle Control (ETC) Actuator– Electric Throttle Control (ETC) Actuator harness is open or shorted– Electric Throttle Control (ETC) Actuator circuit poor electrical connection Symptoms – Engine Light ON (or Service Engine Soon Warning Light) P2101 ACURA OBD Code Description The electronic throttle control system controls the throttle valve opening. The…

P0685 ACURA Electronic Control Module Power Control Circuit Malfunction

Possible causes – Faulty Engine Control Module (ECM) power relay– ECM power relay harness is open or shorted– ECM power relay circuit poor electrical connection– Faulty (ECM) Tech description Check all the ECM fuses, if the fuses are OK try replacing the ECM relay. Symptoms – Engine Light ON (or Service Engine Soon Warning Light)…

P0641 ACURA Sensor Reference Voltage A Malfunction

Possible causes – Faulty Engine Control Module (ECM)– ECM harness is open or shorted– ECM circuit poor electrical connection– Shorted sensor on 5 volt circuit When is the obd code mean? The Engine Control Module (ECM) has detected the sensor 5 volt reference circuit voltage is higher or lower than expected Symptoms – Engine Light…

P0651 ACURA Sensor Reference Voltage B Circuit Fault

Possible causes – Faulty Engine Control Module (ECM)– ECM harness is open or shorted– ECM circuit poor electrical connection– Shorted sensor on 5 volt circuit When is the obd code mean? The Engine Control Module (ECM) has detected the sensor 5 volt reference circuit voltage is higher or lower than expected Symptoms – Engine Light…

P0600 ACURA Multiplexing Error

Possible causes – Faulty Engine control Module (ECM)– Engine control Module(ECM) harness is open or shorted– Engine control Module (ECM) cicuit poor electricl connection– Low battery voltage Symptoms – Engine Light ON (or Service Engine Soon Warning Light) P0600 ACURA OBD Code Description The ECM did not detect communication between modules